Variable Name Unit Sensor Description
TEMP Air Temperature degC TMP117 Measured at 1.9m in non-aspirated Stevenson screen. Average over ~60 seconds.
Continuous measurement mode, 1 second measurement delay, 64 averaged measurements.
DEWP Dew Point Temperature degC TMP117+SHTC3 Calculated from TEMP and RELH. TEMP average over ~60 seconds, RELH instantaneous.
See here
RELH Relative Humidity Percent SHTC3 Measured at 1.9m in non-aspirated Stevenson screen. Instantaneous.
STAP Station Pressure hPa BMP581 Measured at 1.6m through a 3D printed static pressure port. Average over ~40 seconds.
Normal mode, 1Hz data output rate, pressure shadow IIR before, temperature shadow IIR before, pressure oversampling rate 128x, temperature oversampling rate 8x, pressure IIR filter 7x, temperature IIR filter 3x
SEAP Sea Level Pressure hPa BMP581 Calculated from STAP. Average over ~40 seconds.
See here
WSPD Wind Speed m/s Davis Inst. 6410 Measured at 10m. Average over 120 seconds.
WGST Wind Gusts m/s Davis Inst. 6410 Measured at 10m. Maximum 3 second window in 300 seconds.
WDIR Wind Direction Degrees Relative to True North Davis Inst. 6410 Measured at 10m. Weighted average over 120 seconds.
PR24 24 Hour Rain mm Davis Inst. 6466M Measured at 1.6m. Total accumulation over 24 hours.
PR01 1 Hour Rain mm Davis Inst. 6466M Measured at 1.6m. Total accumulation over 1 hour.